EXERGY ANALYSIS ON SHELL AND TUBE TYPE HEAT EXCHANGER

Publication Date : 17/05/2015



Author(s) :

CHETAN UNDHAD , PRAKASH PATEL , NIKUL PATEL , KAUSHIK LATHIYA.


Volume/Issue :
Volume 2
,
Issue 5
(05 - 2015)



Abstract :

The energy analysis gives only energy consumption and energy losses of systems. It does not provide information about internal inefficiency of equipment. The exergy analysis, when applied to process or a whole plant tells us how much is the usable work potential or exergy supplied as input to the system & consumed by process or plant. Take all data fromNIRMA LTD BHAVNAGAR,& SIKA POWERPLANT. After Calculation all data than there are tcond increase exergy is decrease and efficiency is increase Tcond change 306 to 307 there are exergy is 16145.77 to 15732.97 there are efficiency increase to 8% Now Tcond 309 to 310 exergy is 15251 to 15239 there are efficiency 4.1% Now also Tcond 313 to 314 there are exergy 15610 to 15941 to increase efficiency 1.2%. All Data calculate Theoretical and compare with all data Using MATLAB Software


No. of Downloads :

15


Indexing

Web Design MymensinghPremium WordPress ThemesWeb Development

EXERGY ANALYSIS ON SHELL AND TUBE TYPE HEAT EXCHANGER

May 14, 2015